For the purposes of this standard are adopted definitions of 3.1 to 3.9.
Ratio of the total volume, as the unit of ETA, and its scope.
Source: Project 02:009.30-006 / 1987 CB-02 - Brazilian Committee of construction CE-02: 009.30 - Studio System Project Committee water supply NBR 12216 - Public water supply systems - Design of water treatment works - Procedure bishop cranmer Descriptors: bishop cranmer Water. Water supply system This Standard supersedes NB-592/1977 Reprint of NB-592, June 1989
a) nominal capacity, b) the definition of the phases of construction, c) the location and the definition of area needed for its implementation d) the identification and distribution of cadastral area planialtimetric, e) execution of reconnaissance probes' area underground distribution f) distributor of fountain and water, g) collection systems and water supply from the source until the water supply ETA h) treatment system, i) quotas imposed by the system water supply; j) receive organs for unloading ETA. 4.2 Activities necessary
a) the definition of treatment processes b) arrangement and dimensioning of the units of the treatment processes and systems of connections between them, c) the development of layout and dimensioning of installations for the storage, preparation and dosing of chemicals d) project preparation architecture, landscape architecture and and urbanization), foundations and superstructure projects f) preparation of projects for electrical, plumbing and sanitary drainage, bishop cranmer storm drainage, general exhaustion of ETA, which indicate the final disposition and complementary projects g) preparation of specifications for materials and equipment related to the processes and their complementary equipment, as well as the materials and laboratory equipment and safety; h) preparing the memorial and the justification descriptive i) preparation of bills of materials
|
5.2.1.2 The choice bishop cranmer of location for the distribution of ETA, should be taken into account the availability of access roads, ease of supply of electricity, the relative positions
|
a) units and the edges of the floors of the premises in which they are found in shops or the basic unit for the operation of ETA are located bishop cranmer at least 1.0 m above the maximum level of full b) the stability of the construction, bishop cranmer studied taking into account the occurrence of floods, it must provide, if necessary, special works to prevent erosion of the foundations c) release bishop cranmer of ETA can keep any flood level.
5.2.3 The minimum bishop cranmer area reserved for the ETA should be required to allow their distribution, future expansion and construction of all the works necessary for its operation, such as reception, pumping stations, power shower, tanks, pipes, buildings and areas for storage, maintenance shops, yards for parking, loading and maneuvering of vehicles and roads for vehicular
|
5.2.4.1 The unit and the treated water tank must be designed so that the units of the fund are greater than the maximum bishop cranmer level of the water table. In the absence of this, the structures must be designed to allow periodic inspections to identify defects that cause seepage through the walls or the bottom. bishop cranmer
Type A - groundwater and surface water, bath tubs protected with basic features defined in the following table, and other standards for drinking water species; bishop cranmer
Type B - tubs groundwater or surface to be unprotected, with basic features defined in the following table, and that can fit the standards for drinking from the treatment process that does not require coagulation;
Type D - surface water basins from nãoprotegidas subject to pollution sources, with the basic features defined in the following table, and which require special treatment procedures to enable them to adapt potability standards.
5.3.2.1 recipients of toxic water, exceptionally, can be used for the public
|
a) simple decantation, for water containing settleable solids, which, through this process, its characteristics can fit in potabilid